Carrier. Neustar Universal Order Connect User Guide. for E-Bonded and API users. Neustar Order User Insights Guide. for all other users. Neustar OMS Analytics Reporting User Guide. for all users. Get self-service support for product installation and troubleshooting with our manuals, user guides and quick-start guides.
Installation Ingold® Holder 5-port holder Ingold holder 1-port holder, In-line Single Port In-line Holder 5-port holder Ingold holder 1-port holder, In-line Contact Technical Service for NovaSeptum ® or NovaSeptum ® GO preloaded Single Use Holders installation. 2. When a rack is used, install the rack then hang the bottles or bags on the rack.
Answer –towel stayes dry (Syringe was clogged with septum) Pull plunger out top, add solvent and replace plunger will usually dislodge septum particle (should hear a little pop) If you can’t dislodge plug, Replace syringe Reassemble the Injector & Re-inject Logical Steps Taken to Find Peaks (most of our problems are leaks and plugs)
During installation approximately 3 cm (1 inch) of column must be removed from both ends to remove any septum material that may be blocking the column. This ensures the column is open and ready for use. To install the column follow the protocol given below: 1. After taking out the old column, remove any graphite
Septum nut base for 320 mm assembly 19245-80521 1 q Septum nut base for 530 mm assembly G1545-80520 1 q Spring 19245-60760 1 q Inserts For 200 µm columns, 1 ring 19245-20510 5 q For 250 µm columns, 6 rings 19245-20515 5 q For 320 µm columns, 5 rings 19245-20525 5 q Inserts for capillary columns 19245-20580 5 q Continued on the next page. FID
• Replace inlet septum to stop septum bleed • Replace syringe and autosampler wash solvent • Perform full injector port maintenance and replace consumables Sample is undergoing “flashback” within injector port • Use less solvent and/or a higher column & split flow rates • Lower injection port temperature
the right to reschedule the installation dependent upon the readiness of your laboratory. • Should your site not be ready for whatever reasons, please contact Aijiren as soon as possible to re-schedule any services that have been purchased. • Other optional services such as additional training, operational qualification (OQ) and
Aug 5, 2021 · We had issues with a leak afterwards with N2 values varying from 22 to 16% and O2 values varying from 7 to 5%. I tightened fittings, replaced inlet and septum. Nothing helped. Mass spec does not seem to be an issue. When I read the installation instructions and it seems a ferrule is needed.
4. Select the appropriate septum for your lab operations. PerkinElmer offers multiple septum product lines for different applications, see Table 1. 5. Using a gloved hand or tweezers, place a fresh septum in the slot on the underside of the inlet cap. Note: if your septum has an indented needle guide, ensure the indented
3-WAY 120 Septum 3-WAY 90 Septum 4-WAY 90 Septum 2-WAY 90 Septum 2-WAY 60 Septum 2-WAY 45 Septum 180 D Septum RACEWAY SEPTUM INSTALLATION (Optional) Level Panels – Per standard practice, level panels using FLAT ½ inch open end wrench. STEP 1 STEP 2 Stage Base Covers – Slide base covers under leveled panels as shown at right and leave OPEN.
Tips to Maximize Septum Life, Minimize Septum Leaks –Use Aijiren Gold Standard, HP Point, 23-26 gauge taper syringes. The point style cores septa significantly less when used with CenterGuide Septa. Taper minimizes septum coring/wear. –Use Aijiren CenterGuide Septa. The molded hole minimizes septa coring, counter-intuitive, but true.
Aijiren A GC Maintenance and Troubleshooting Manual is a comprehensive guide for users of the Aijiren A gas chromatograph. It covers the installation, operation, maintenance, and troubleshooting of the instrument and its components. It also provides useful tips, diagrams, and procedures for optimal performance and reliability.
Nov 10, 2022 · Steps To Follow: Tools Required: Replacement septum Tweezers Gloves Warning: The oven and/or inlet may be hot enough to cause burns. If the inlet is hot, wear heat-resistant gloves. If possible, set the temperatures to cooler values during maintenance activities
Refer to the B Automatic Liquid Sampler Installation, Operation and Maintenance manual for additional information. • Check that the GC septum nut is not too tight. • Check that the syringe is installed correctly into the syringe carriage. • Check that the needle support and guide are clean. Remove any residue or septum deposits.