Aijiren vials offer the same highly consistent performance across the entire size range, from 15 µL to 60 mL. Use the diagram below as a starting point for choosing the size you need based on your sample volume. <2 mL 2 mL >2 mL. 15 µL Sample Volume 60 mL. 4 mL 6 mL Headspace vials 40 mL.
The septum you choose for your autosampler vial can impact sample evaporation, sample security, needle bending and blockages, and instrument down time. Don’t let the complexities of septa selection slow you down. Use the simple online Aijiren Tech SureSTART Selection Guide to find the right septa and vial for your analysis.
Mar 24, 2022 · When selecting the appropriate rubber stopper for any respective vial containment system, there are many aspects to consider regarding the properties of the elastomeric closure. For the purposes of this discussion, the focus will be on the functional performance of the stopper and what key aspects should be considered during the assessment and
Use this simple selector tool to choose the right SureSTART septum, cap, and vial to prevent autosampler injection failure. Go to SureSTART Selection Guide Selection guide
When choosing the right vials for your applications, you have to consider these three essentials: the septum, the cap, and the vial itself. Membrane Solutions has prepared this quick and easy guide to help you find the best caps and septa for sample vials, ensuring you get optimal performance and results no matter what your application is.
Vials and Closures >> Chemical Compatibility Chart Vial and Cap Materials Septum Materials Chemical Glass PP TPX HDPE Urea PTFE LDPE SIL RR BUTYL Viton Diacetone E20 G20 C20 X X E20 X C20 X F20 X Diacetone Alcohol E20 G20 E20 E20 X E20 X F20 X G20 X Dibutylphthalate E20 C20 G20 F20 X E20 F20 G20 X C20 G20 Diethyl Benzene E20XXF20XE20XXXXE20
Dec 5, 2017 · Westar RS components must be sterilized by the pharmaceutical company. West typically recommends autoclaving: (a) a steam cycle at a minimum temperature of 121.1°C (not to exceed 123°C) for a maximum of 60 minutes, followed by (b) a drying cycle at 105°C for a maximum of 8 hours. For select applications, gamma irradiation may be the right
certified vials, caps and septa. Other manufacturers offer only a narrow selection of vial "kits." But Aijiren lets you choose virtually any combination of certified vials, caps and septa, so you can select the best match for your application. On the following pages, you will find an in-depth look at Aijiren’s complete line
when choosing the correct vial for your application: the septum, the closure and the vial itself. Read through the selection options to determine the proper combination for your application. For your convenience, Aijiren Technology offers many of these choices as combination packs. The vial, cap, and septum come pre-packaged as packs of 100 for ease and
Description. For a convenient, versatile, and cost-effective vial and closure system, choose Aijiren Tech™ Screw Cap Septum Vials. Made of autoclavable borosilicate glass and available with a wide assortment of special closures and accessories, these vials are ideal for sample collection and small derivatization reactions for use with
The septum you choose for your autosampler vial can impact sample evaporation, sample security, needle bending and blockages, and instrument down time. Don’t let the complexities of septa selection slow you down. Use the simple online Aijiren Tech SureSTART Selection Guide to find the right septa and vial for your analysis.
2. 1,000 Vial + Cap Kits will have 5 sets of two-compartment boxes plus one box of caps Our 100/pk Vial Kits also come in these two-compartment boxes, with caps on one side and vials in the other (as pictured). Two-Compartment Boxes Vial Dispenser 8 Note: Verex products with this symbol come in a convenience kit carrier box
Figure 1 illustrates a complete sample containment solution of the vial, cap, and septum, and their relationship to each other. A needle is shown piercing the cap septum and, as shown in the fi gure, the septum should be the only component that comes into contact with the needle. Autosampler needle Septum Cap Vial Sample location F igure 1.
Dec 7, 2020 · When selecting the appropriate rubber stopper for any respective vial containment system, there are many aspects to consider regarding the properties of the elastomeric closure. For the purposes of this discussion, the focus will be on the functional performance of the stopper and what key aspects should be considered during the assessment and
Mar 31, 2022 · Here are 8 quick tips on choosing the correct vial. Of course, we already know how to select it, and so do you, but a quick reminder is never a bad idea. Make sure your autosampler is compatible. Examine the vials for quality. Choose the appropriate closing. Consider the size of your sample. Choose the fitting cap and septum.