Products
Leading Supplier of Chromatography Vials Since 2007
Position :
Home » News » Crimp Top Vials » Understanding the Benefits of Septum Liners for Improved Gas Chromatography Performance

Understanding the Benefits of Septum Liners for Improved Gas Chromatography Performance

Glass Inlet Liners for Gas Chromatography – PerkinElmer Reduces adsorption of the polar and active solutes on the liner wall, which is more or less inactive Ensures compatibility with the cho...
Product Introduction

Glass Inlet Liners for Gas Chromatography - PerkinElmer

Reduces adsorption of the polar and active solutes on the liner wall, which is more or less inactive Ensures compatibility with the chosen injection mode Optimizes the flow in the injector Ensures that peaks are as narrow as possible, resulting in maximum resolution and sensitivity depending on the chosen injection mode

Troubleshooting Chromatographic Contamination Ghost peaks

• Clean carrier/makeup gas and delivery tubing • Clean solvent • Syringe (It is important to use sufficient solvent washes in autoinjector to avoid cross contamination from sample to sample.) • Inlet liner/septum • Column • Detector plumbing and base weldment When diagnosing chromatographic problems it is very important to use tests

Basics & Fundamentals - Gas Chromatography - Shimadzu

Basics & Fundamentals: Gas Chromatography ˜ow rate for separation septum and improve separation with solvent peak to this. The split method is a relatively simple sample injection method. Higher quality data can be obtained by understanding and analyzing features well. 2-2. Splitless Injection Method

Gas Chromatography - What It Is and How It Works - ThoughtCo

Oct 13, 2019 · How Gas Chromatography Works. First, a liquid sample is prepared. The sample is mixed with a solvent and is injected into the gas chromatograph. Typically the sample size is small -- in the microliters range. Although the sample starts out as a liquid, it is vaporized into the gas phase. An inert carrier gas is also flowing through the

Understanding your GC Inlet and How to Maintain it. - Aijiren

• liner dependent (use the Pressure-Volume Calculator) • 2 uL maximum Reduce Split Ratio • go from 50:1 to 10:1 • 10:1 practical lower limit for liquid injections (for 250 - 320 um i.d. columns) • 1:1 possible for gas injections with correct liner • Keep TOTAL INLET FLOW at 20 mL/min or higher

Recent update of the various sources originating ghost peaks

Dec 6, 2022 · The injector port is an essential part of GC, but it works as a potential source for generating ghost peaks. The improper evaporation or decomposition of the sample in the injector port generates these peaks [9], so it can be considered a direct or indirect source of ghost peaks [3].

Gas chromatography - Wikipedia

Gas chromatography ( GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [1] In preparative chromatography, GC can be

GC Method Developement - Aijiren

Choose a liner with enough volume to accommodate the vaporized sample. Important, especially for polar solvents with large vapor volumes. If vapor volume of sample exceeds liner volume, samples may back up (backflash) into carrier gas supply lines, causing ghost peaks and reproducibility problems in chromatography.

Gas Chromatography Liner Selection Guide

Liner, focus Peter Morgan, Aijiren Tech Scientific, Runcorn, Cheshire, UK Abstract The liner serves an important function in allowing a sample which is injected in the liquid phase to pass into the gaseous phase and onto the GC column. Choosing the most suitable liner from the wide selection available can be confusing.

Replacing the Inlet Septum for Split/Spitless and - Aijiren

Nov 10, 2022 · Remove the septum retainer nut. (See Figure 1 for full replacement in steps 3 to 8) Use tweezers to remove the septum from the insert assembly. Do not gouge or scratch the interior of the insert assembly; If septum has needle guide recess in one side, ensure that side is facing up. Press new septum firmly into insert assembly. Replace septum

Simplifying GC Syringes and Sample Introduction - Aijiren

Septum maintenance: TIC of an inlet/vial septum Septa contamination in wash vials or inlet liners can be diagnosed by looking for siloxane polymers in your total ion chromatogram. Each peak in the chromatogram corresponds to a cyclized (ring structure) siloxane molecule. These molecules fragment with very similar patterns. Example spectrum:

12.4: Gas Chromatography - Chemistry LibreTexts

Jun 15, 2020 · 12.4: Gas Chromatography. In gas chromatography (GC) we inject the sample, which may be a gas or a liquid, into an gaseous mobile phase (often called the carrier gas). The mobile phase carries the sample through a packed or a capillary column that separates the sample’s components based on their ability to partition between the mobile phase

The Clarus GC Family – Performance you can rely on from the

Clarus Gas Chromatograph The Clarus GC Family – Performance you can rely on from the leader in Gas Chromatography and sample-handling solutions With more than 50 years’ experience in Gas Chromatography (GC), the PerkinElmer® family of Clarus® GC instruments can be depended upon to meet the most demanding performance and

Leaks in a GC System - Chromatography Today

As needed Clean when performance deteriorates to remove contamination and to restore the electrostatic properties of the ion lens system. Replace scratched parts to maintain optimal performance. Gas management Gas purifiers (carrier Gas / detector gas) Every 6 to 12 months Replacement schedule is based on capacity and grade of gas. In general

KB000269: What indicates the need to change the septum or liner?

Information as to the indications that the gas chromatography septum or liner need to be replaced.

Related Products
Send us a message
Zhejiang Aijiren Technology, Inc. is a global supplier of life-science, chemistry, laboratory consumables, etc. Our major products are high performance liquid chromatography & gas chromatography consumables such as Chromatography Autosampler Vials with closures, inserts, crimper and syringe filters, etc; Water analysis consumables such as COD test tube.
Copyright 2021 Zhejiang Aijiren Technology, Inc. All Rights Reserved.